Friday 8 January, 2010

WELDER PERFORMANCE QUALIFICATION - PART 2

 ASME sec IX , the chart  461.9 specifies test positions and corresponding qualification positions

 * PLATE WELDER CAN WELD PIPE BUT OD SHOULD BE MORE THAN 73MM

Approval Range
Extent of approval is very well explained in QW461.9. Take particular note of welding positions which are also explained in QW461, for example to qualify a fillet weld in the normal horizontal-vertical position with a groove weld, the groove weld must be qualified in at least the 2G position. The welding positions defined in QW461.1.& QW461.2 should be referred to in the WPS. The position designations: 1G ,2G ,3G ,4G ,5G ,6G (Groove Welds) and 1F ,2F ,3F ,4F (Fillet Welds) are test positions